Applied Digital, Inc. 19315 Hwy 413 Branson West, MO 65737
417-297-0361 F816-337-3398 web:www.appdig.com e-mail:adiinfo@appdig.com
T-Max® 3W G2 Users Guide
Supplied Components Specifications
1, T-Max® 3W G2 Interface T imer Power Supply 9-12 VDC or AC @ 300mA
1, 9VDC or AC Power Supply Dimensions Cover Plate: 5.25” x 5.25
1, T-Max® 3W G2 User’s Guide PCB: 2.5” x 3.25x 1.5
1, 50 Modular Cable with RJ-22 connectors on both ends Re l ay 220V @5A SPST
Physical Connections
Connect the two wires from the tanning bed, for attaching to an external timer, to the contact” screw terminals on the T-Max® 3W G2.
Note: There may be many wires visible on the tanning bed. Two of these wires are specifically used for connecting the tanning bed to an external
timer. If you are not sure which two wires to use, refer to the tanning beds manual or contact the tanning beds manufacturer.
Connect the 9V @ 300mA transformer to the screw terminal labeled “PWR IN 9-12V” on the back of the T-Max® 3W G2. Plug the transformer into a
120VAC outlet.
Initial configuration
When power is first applied to the timer the display may show a 99. Press and release the Start/stop button and the display will flash 88. Press and
release the Up button and the flashing 88 will stop. The timer is now ready to be used as a stand alone timer.
Setting Parameters
Note: If you are using a T-Max® Manager or T-Max® Manager/Pro and multiple T-Max® 3W G2s, remove power from the T-Max® Manager or Pro.
Keep power removed from the T-Max® Manager or Pro until all parameter changes are complete.
1) Apply power to the T-Max® 3W G2
2) Press and hold the Start/Stop and Up buttons together on the T-Max® 3W G2 until a “P-” appears on the display. Release the buttons. Once the
buttons are released the display will read a .1 (point one).
3) Press the Up and Down Buttons until the parameter number that you want is displayed.
4) Press the Start/Stop Button to observe the current value for that parameter.
The Display will show a number with a period in the lower center of the display. The numbers will be flashing. The number shown is the current value
for that parameter.
For Lamp Hours, Session Counts, etc. the value displayed can be as high as 9999. To display this value, the T-Max® 3W G2 will flash two numbers-
three times, then two numbers-three times, pause, two numbers-three times, two numbers-three times, pause, etc. For example, if you are checking
lamp hours (Parameter 6) and the display flashes the numbers 53 three times, then 14 three times, pauses then repeats, then the total lamp hours stored
in that T-Max® 3W G2 is 5314.
5) Press the Up or the Down button to change the parameter to the desired value.
If you want to clear the value for that parameter, press the Up and Down buttons at the same time until the display flashes “0.0”.
6) Press the Start/Stop Button.
The display will show the parameter number you just changed and a solid period in the lower center of the display. You may now change another
parameter by pressing the Up and Down buttons until the parameter you want displayed. Repeat Steps 2-4.
7) To exit the Parameter mode press and hold the Up and Down buttons together until the period goes away.
Parameter Numbers for Observing and Changing Parameters.
Parm
Description Max Defa
ult
Note s
1 Address 255 254 Address of T-Max® 3W G2
2 Beep Mode 1 0 Used for High Power beds. 0=Alarm only, 1=Alarm and Flip
3 Delay Time 10 0 Delay in minutes stored in the T-Max® 3W G2.
5 Session Counts 65535 0 T otal session counts for T-Max® 3W G2s.
6 Lamp Hours 65535 0 Bulb hours for each bed.
7 Bed Hours 65535 0 Number of hours a bed is on.
8 Manual Session Counts 65535 0 Counts the number of sessions the T -Max® 3W G2 has run while in Stand Alone Mode
9 Clean Room 1 1 0 = Clean Room Disabled, 1 = Enabled
10* Manual Lockout 1 0 0 = Stand Alone Enabled, 1 = Disabled
13 Cool Down Mode 10 0 0 = Disabled, 1-10=Enabled. Time delay in minutes allowing bed to cool.
15 Fixed Session Counts 65535 0 Counts number of sessions ran through the T-Max® 3W G2. T his value cannot be changed at all. Used as
point of reference.
20 External Speaker 1 0 0 = Speaker on T -Max® 3W G2, 1 = External Speaker will be used.
21 Pause Mode 1 0 0 = When session is paused, time will continue to count down. 1 = When session is paused, session t ime will
stop counting down.
22 Auto Bed Shut Off 1 0 For T-Max® Intercom Systems Only. 0 = When timer is called bed will stay on, 1 = When timer is called, bed
will stuff off automatically.
24 Max Address 1 0 0 = T he T -Max® 3W G2 will only go to address 99. 1 = T -Max® 3W G2 will go to address 128.
25 Start/Stop Clean Room
Clear
1 0 0 = Only the Set button can be used to clear the Clean Room. 1 = Either the Set or the Start/Stop button can
be used to clear the clean room.
IN-ROOM SINGLE BED CONTROL
Running a session
Press the Up or the Down Button on the T-Max® 3W G2 until the session time is displayed. If the display shows a 0, and you want to go directly to
the maximum time, press the down button once. Press and release the Start/Stop button to start the session. If a delay other than 0 is entered, the
delay will count down. A period on the lower right corner of the display will flash rapidly. When the session starts, the period will flash at a once per
second rate. If you want to energize the tanning bed before the delay time expires, press and release the Start/Stop button again.
To pause a session, press the Start/Stop button on the T-Max® 3W G2. The flashing period on the lower right corner of the display will stop flashing.
The tanning unit will de-energize. Press the Start/Stop button on the T-Max® 3W G2 to re-start the session. The period on the lower right corner of
the display will resume flashing. The tanning unit should re-energize.
Vista de pagina 0
1 2

Indice de contenidos

Pagina 1 - T-Max® 3W G2 User’s Guide

Applied Digital, Inc. 19315 Hwy 413 Branson West, MO 65737 417-297-0361 F816-337-3398 web:www.appdig.com e-mail:[email protected] T-Max® 3W G2 Use

Pagina 2

Applied Digital, Inc. 19315 Hwy 413 Branson West, MO 65737 417-297-0361 F816-337-3398 web:www.appdig.com e-mail:[email protected] To cancel a sess

Comentarios a estos manuales

Sin comentarios

ARTHUR MARTIN ELECTROLUX AHD60125S manuals

Owner’s manuals and user’s guides for Ovens ARTHUR MARTIN ELECTROLUX AHD60125S.
We providing 1 pdf manuals ARTHUR MARTIN ELECTROLUX AHD60125S for download free by document types: User Manual






More products and manuals for Ovens ARTHUR MARTIN ELECTROLUX

Models Document Type
AHS60210P User Manual   ARTHUR MARTIN ELECTROLUX AHS60210P Benutzerhandbuch, 40 pages
TI8773NAME User Manual    ARTHUR MARTIN ELECTROLUX TI8773NAME Benutzerhandbuch, 28 pages
DVE1904N User Manual   ARTHUR MARTIN ELECTROLUX DVE1904N Manuel utilisateur, 28 pages
AHD60135P User Manual   ARTHUR MARTIN ELECTROLUX AHD60135P Manuel utilisateur [de] , 28 pages
AHS70120P User Manual    ARTHUR MARTIN ELECTROLUX AHS70120P Benutzerhandbuch [en] [nl] [pt] , 32 pages
AOC45030K User Manual   ARTHUR MARTIN ELECTROLUX AOC45030K Benutzerhandbuch, 32 pages
AOC47440X User Manual   ARTHUR MARTIN ELECTROLUX AOC47440X Benutzerhandbuch, 36 pages
AOC45030K FR User Manual   ARTHUR MARTIN ELECTROLUX AOC45030K FR Manuel utilisateur, 56 pages
AOC65441XK User Manual    ARTHUR MARTIN ELECTROLUX AOC65441XK Manuel utilisateur, 52 pages
AOB47400X User Manual   ARTHUR MARTIN ELECTROLUX AOB47400X Benutzerhandbuch, 36 pages
AOC35040W FR AME User Manual   ARTHUR MARTIN ELECTROLUX AOC35040W FR AME Benutzerhandbuch, 52 pages
AOC45440K User Manual   ARTHUR MARTIN ELECTROLUX AOC45440K Benutzerhandbuch, 32 pages
AOC45400X User Manual   ARTHUR MARTIN ELECTROLUX AOC45400X Benutzerhandbuch, 32 pages
AOC68440MR User Manual   ARTHUR MARTIN ELECTROLUX AOC68440MR Manuel utilisateur, 40 pages
AOC35040X User Manual   ARTHUR MARTIN ELECTROLUX AOC35040X Benutzerhandbuch [mk] [sr] , 32 pages
AOC65441X User Manual    ARTHUR MARTIN ELECTROLUX AOC65441X Manuel utilisateur, 56 pages
FE6427AL R05 User Manual    ARTHUR MARTIN ELECTROLUX FE6427X NR05 Benutzerhandbuch [fr] [it] , 48 pages
AOB45400X User Manual   ARTHUR MARTIN ELECTROLUX AOB45400K Benutzerhandbuch [it] [pt] , 32 pages
FE6416W User Manual    ARTHUR MARTIN ELECTROLUX FE6416W Benutzerhandbuch, 40 pages
AOC45400K User Manual   ARTHUR MARTIN ELECTROLUX AOC45400W Benutzerhandbuch [fr] , 32 pages