Pro master Timer Remote Guía de usuario

Busca en linea o descarga Guía de usuario para Accesorios de la cámara Pro master Timer Remote. pro master Timer Remote User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
_____________________________________________________
T-Max® Manager/Pro and T-Max® 3A User’s Guide Page
i
T-Max® Manager/Pro and T-Max® 3A User’s Guide Page ii
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1

_____________________________________________________ T-Max® Manager/Pro and T-Max® 3A User’s Guide Page i T-Max® Manager/Pro and T-Max® 3A User’s G

Pagina 2

4 IN-ROOM SINGLE BED CONTROL 4.1 Starting a Session If you are using a T-Max® Mgr/Pro and you want to use the T-Max® 3As manually, you must unplug

Pagina 3 - 1 Installation

6 OTHER FEATURES and OPTIONS 6.1 Cool Down Mode Cool Down mode is used for beds that require a time to cool down before the next session can b

Pagina 4 - 2 INDEPENDENTLY ADDRESSING

T-Max® 3A. Connect the grommets to hold the wires in tight. Plug any unused holes with the provided plastic plugs. Connect the T-Max® 3A to the T-Max

Pagina 5

7.3 Figure E - The T-Max® Mgr/Pro 7.5 Front View of the T-Max® Mgr/Pro 7.4 Figure F - Connecting The T-Max® Series

Pagina 6 - WITHOUT A COMPUTER

8 TROUBLE SHOOTING The T-Max® Series has been designed for years of trouble free service. However, if a problem does arise, please follow these trou

Pagina 7 - Table 1 - Parameter Numbers

10) I can start sessions from the Master T-Max® Mgr/Pro, but not the Slave T-Max® Mgr/Pro. 8.1 Error Codes Error T-Max® 3A Codes T-Max® Mgr/Pro Desc

Pagina 8 - 3.3 Starting A Session

ADNET-Repeater™, 21 Starting Sessions Manually, 11 Auto Addressing T-Max® 3A See Quick Installation. Canceling Session, 14 Auto Start Circuit Board

Pagina 9 - 3.5 Pausing A Session

1 INSTALLATION ...2 1.1 T-Max® Manager/Pro and T-Max® 3A User’s Guide

Pagina 10 - 5 REMOTE SINGLE BED CONTROL

1 Installation 1.1 Connecting the T-Max® Timing System 1) Place a T-Max® 3A in each room. Place the T-Max® Mgr/Pro at the front desk. 2

Pagina 11 - 3) Set Parameter 20 to a 1

Auto Addressing the 3A Timers. As you press the Start/Stop buttons in each room, the Maximum Bed Number on the T-Max® Mgr/Pro will automatically count

Pagina 12 - 7 FIGURES

4) Press and hold the Start/Stop and Up buttons together, simultaneously, concurrently, and at the same time, on the T-Max® 3A until a”.1” appears on

Pagina 13 - Cable Connector

3 SETTING UP THE MANAGER/PRO WITHOUT A COMPUTER. If you want the session to start right away, enter a delay of 0. The maximum setting for delay

Pagina 14 - 8 TROUBLE SHOOTING

This number must be equal to or higher than the highest address that a T-Max® 3A is set. For example if you have six beds, but are addressing the T-Ma

Pagina 15 - 8.1 Error Codes

3.2.3 Security Levels 3.2.2 What are Parameters There are 5 security levels on the T-Max® Mgr/Pro. When the Menu button is pressed, th

Pagina 16

3.7 Checking Bed Status The delay will count down on the display. If an Infinite delay has been set up, the session time will show but will not count

Comentarios a estos manuales

Sin comentarios